Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Acta odontol. Colomb. (En linea) ; 9(2): 24-35, 2019. ilus, Graf
Article in Spanish | LILACS, COLNAL | ID: biblio-1024515

ABSTRACT

Objetivo: comparar el grosor óseo palatino bilateral e identificar zonas seguras para inserción de miniimplantes. Métodos: se llevó a cabo un estudio transversal que incluyó 100 tomografías de haz cónico (CBCT) pretratamiento de pacientes que asistieron a la Especialidad de Ortodoncia en la Universidad Autónoma de Nayarit (UAN). Las imágenes fueron orientadas utilizando el mismo protocolo. En el corte sagital, las mediciones se realizaron de los 0 a los 24mm, con intervalos de 3mm entre cada una, con la primera medición en el borde posterior del foramen incisivo. Las mediciones del grosor palatino se realizaron en el corte coronal a los 2, 4, 6 y 8mm de la sutura media palatina hacia ambos lados. Resultados: se encontró mayor grosor en la zona anterior en las medidas sagitales de 0 mm y 3 mm, a diferencia del resto del paladar. Se hallaron diferencias estadísticamente significativas al comparar los valores tanto sagitales como transversales. Con la prueba Post Hoc de Tukey no se encontraron diferencias estadísticamente significativas al comparar el lado derecho con el izquierdo en cada una de las medidas transversales. Conclusiones: no se encontraron diferencias significativas entre los dos lados, se determinó como zona segura la región anterior del paladar de 0mm a 6mm y es primordial la CBCT en todos los pacientes con indicación de miniimplantes en paladar.


Objective: Bilateral comparison of palatal bone thickness and identification of safe areas for insertion of mini implants. Methods: Cross-sectional Study that included 100 Cone beam computed tomography (CBCT) pretreatment, of patients who attended the Orthodontic Specialty at the Autonomous University of Nayarit (UAN). The images were oriented using the same protocol. In the sagittal plane, measurements were made from 0 to 24mm, with intervals of 3mm between each, being the first measurement at the posterior rim of the incisive foramen. Measurements of the Palatine thickness were made on the coronal plane at 2, 4, 6 and 8mm of the mid palatal suture on both sides. Results: Greater thickness was found in the anterior area in the sagittal measurements of 0mm and 3mm, unlike the rest of the palate. Statistically significant differences were found when comparing both sagittal and transverse values. With Tukey's post hoc test no statistically significant differences were found when comparing the right and left sides in each of the cross measures. Conclusions: No significant differences were found between the two sides, the anterior palatal region of 0mm to 6mm was determined to be safe and CBCT is paramount in all patients in whom mini-implants are to be placed on the palate.


Subject(s)
Adolescent , Adult , Orthodontics , Orthodontic Anchorage Procedures , Palate , Bone and Bones , Cone-Beam Computed Tomography , Mexico
SELECTION OF CITATIONS
SEARCH DETAIL